Facility Evaluation Report

El Molino Rose Villa, Pasadena05/08/2025Licence 198601951

Capacity6
Census0
Date signed05/09/2025 01:30:01 PM
Name of licensing program analystSanjay Vaid
Name of licensing program managerFernando Fierros
The inspector’s account

Licensing Program Analyst (LPA) Alberto Lopez conducted the required annual inspection. LPA arrived unannounced and explained the purpose of the visit LPA met with Andy and Yelly Kohler, who assisted with the inspection today. The facility is licensed for 6 residents ages 60 and over. The fire clearance is approved for Six (6) non-ambulatory residents. Currently there are zero (0) residents at the facility, three (3) residents have been re-located at facilities nearby and one (1) resident has gone home with family. The renovations to the facility for Eaton Canyon Fires caused smoke damage to the facility. Renovations for disaster readiness being implemented.

LPA utilize the Compliance and Regulatory Enforcement tools for the visit today and observed the following:

1. Infection Control. Facility has sufficient PPE supplies and has an Infection Control Plan.

2. Physical Plant and Environmental . The facility is a single-story house. The facility includes living room, dining area, kitchen, four clients’ bedrooms, 2 shared bedrooms, 2 private bedrooms, two bathrooms. Laundry area and an detached garage. LPA inspected the carbon monoxide detector and is working probably. The smoke detectors are in each room and common area, and they are working, hardwired and interconnected. Water temperature in two bathrooms and kitchen, a 105 -120 deg F. All the sharp knives and utensils are locked in the kitchen cabinet. All the cleaning supplies and chemicals are locked in the laundry room and locked in the outdoor storage. The facility has sufficient personal hygiene products for clients to use. All clients rooms are currently furnished with chairs and have required beddings. All the bathrooms are clean, sanitized, and operational. The exit and passageway is safe and clear of obstructions.

3. Operational Requirements. The facility maintained a fire clearance approved by the fire department which 6 may be non-ambulatory. Currently all the clients in the facility are non-ambulatory. The facility also has shaded area with table and chairs for client to utilize for outdoor activity. The last fire/disaster drill was conducted on 06/07/2024. Currently there are zero (0) residents at the facility. Contined on 809C...

Source: California Department of Social Services, Community Care Licensing. Methodology · Report a correction